TCC-82 Port-powered RS-232 isolator with 4 KV isolation and 15 KV serial ESD protection

Highlights

  • 4 channels of 4 KV RMS isolation for 1 minute
  • External power source supported but not required
  • 15 KV serial ESD protection
  • Automatic baudrate detection
  • Compact size

Description

Includes

  • 1 x TCC-82 unit
  • 1 x installation guide
  • 1 x warranty statement
  • 1 x USB power cord (50 cm) x 2

Specs:

Operating Temperature
0 to 60°C (32 to 140°F)

Source of Input Power
RS-232 port (TxD signal) or power input jack

Input Voltage
5 to 12 VDC

Power Consumption
20 mA @ 5 V

Overview:

The TCC-82 provides full electrical isolation for bi-directional serial communication between two RS-232 devices in a compact, industrial-grade package. Both sides of an RS-232 connection are isolated optically to provide perfect protection against lightning surges, accidental high voltage shorts, and ground loops.

The built-in, wide range isolators are tested to ensure that they can withstand more than 4 KV rms input to output for 1 minute. This means that the TCC-82 not only meets the requirements of general serial data communications, but also the high standards required by industrial automation and medical applications.

The TCC-82 protects the TxD and RxD data lines, and also protects the RTS and CTS handshake lines for a total of 4 isolated channels to provide complete protection of your RS-232 applications.