Description
Overview
The MB3170 and MB3270 are advanced Modbus gateways that provide maximum flexibility for integrating industrial Modbus networks of all types and sizes. They are designed to integrate Modbus TCP, ASCII, and RTU devices in almost any master and slave combination, including serial master to serial slave, or simultaneous serial and Ethernet masters. A special priority control feature allows urgent commands to obtain immediate response. All models are ruggedly constructed, are DIN-rail mountable, and offer built-in optical isolation for serial signals as an option.
Integration of TCP masters without alteration to Modbus RTU/ASCII network or software
The MB3270 can integrate Modbus TCP with Modbus RTU/ASCII,without modifying the existing Modbus RTU/ASCII architecture or software. With the serial redirector function, a serial master can maintain direct access to serial slave devices through a specially mapped serial port. This allows the serial and TCP masters to access serial slaves simultaneously.
Cascading Ethernet ports for easy wiring
Advanced models of the MGate™ MB3000 series have two Ethernet ports to make network wiring easier. Dual Ethernet ports allow users to string multiple Modbus gateways together using standard RJ45 Ethernet cables, eliminating the need for a separate Ethernet switch.
Redundant power inputs
Advanced models of the MB3000 series have dual power inputs for greater reliability. The power inputs allow simultaneous connections to two live DC power sources, so that continuous operation is provided even if one power source fails. The higher level of reliability makes these advanced Modbus gateways ideal for demanding industrial applications.
Warning by relay output
A relay output is provided for the Ethernet link and power input status. The relay output gives maintenance engineers an additional tool for troubleshooting and maintenance.
Priority control for urgent commands (Patented)
As Modbus networks increase in size and complexity, the lag time between commands and responses becomes a major concern. Advanced models of the MB3000 series provide a priority control function for urgent commands, allowing users to force certain commands to get an immediate response. Depending on your system’s requirements, different methods are available to define which commands receive priority.
• Ethernet Interface | |
Number of Ports | 2 (1 IP) |
Speed | 10/100 Mbps, Auto MDI/MDIX |
Connector | 8-pin RJ45 |
Magnetic Isolation Protection | 1.5 KV built-in |
• Serial Interface | |
Number of Ports | MB3170/3170I: 1 MB3270/3270I: 2 |
Serial Standards | RS-232/422/485, software selectable |
Connectors | MB3170/3170I: DB9 male for RS-232, Terminal block for RS-422/485 MB3270/3270I: DB9 male x 2 |
ESD Protection | 15 KV for all signals |
RS-485 Data Direction Control | ADDC® (automatic data direction control) |
Pull High/Low Resistor for RS-485 | 1 KΩ, 150 KΩ |
Terminator for RS-485 | 120 Ω |
• Serial Communication Parameters | |
Data Bits | 7, 8 |
Stop Bits | 1, 2 |
Parity | None, Even, Odd, Space, Mark |
Flow Control | RTS/CTS, DTR/DSR (RS-232 only) |
Baudrate | 50 bps to 921.6 Kbps |
• Serial Signals | |
RS-232 | TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND |
RS-422 | Tx+, Tx-, Rx+, Rx-, GND |
RS-485-4w | Tx+, Tx-, Rx+, Rx-, GND |
RS-485-2w | Data+, Data-, GND |
• Software | |
Operation Modes | RTU Slave, RTU Master, ASCII Slave, ASCII Master |
Configuration Options | Web Console, Serial Console, Telnet Console, Windows Utility |
Utilities | MGate Manager for Windows 98/ME/NT/2000, Windows XP/2003/Vista/2008/7 x86/x64 |
Multi-master and Multi-drop | Master mode: 32 TCP slaves Slave mode: 16 TCP masters (request queue 32-deep for each master) |
Bonus Features | Smart Routing, Serial Redirection, Priority Control |
• Physical Characteristics | |
Housing | Plastic |
Weight | MGate MB3170: 360 g MGate MB3270: 380 g |
Dimensions | Without ears: 29 x 89.2 x 118.5 mm (1.14 x 3.51 x 4.67 in) With ears extended: 29 x 89.2 x 124.5 mm (1.14 x 3.51 x 4.90 in) |
• Environmental Limits | |
Operating Temperature | Standard Models: 0 to 55°C (32 to 131°F) Wide Temp. Models: -40 to 75°C (-40 to 167°F) |
Storage Temperature | -40 to 85°C (-40 to 185°F) |
Ambient Relative Humidity | 5 to 95% (non-condensing) |
• Power Requirements | |
Input Voltage | 12 to 48 VDC |
Power Connector | Terminal block |
Power Consumption | MGate MB3170: 435 mA (max.) MGate MB3170I: 555 mA (max.) MGate MB3270: 435 mA (max.) MGate MB3270I: 510 mA (max.) |
Relay Output | 1 Digital relay output to alarm (normal close): Current carying capacity 1 A @ 30 VDC |
• Standards and Certifications | |
Safety | UL 60950-1, EN 60950-1 |
Hazardous Location | UL/cUL Class I Division 2 Groups A/B/C/D, ATEX Zone 2, IECEx (for -IEX models) |
EMC | CE, FCC |
EMI | EN 55022 Class A, FCC Part 15 Subpart B Class A |
EMS | EN 55024, EN 61000-4-2 (ESD) Level 3, EN 61000-4-3 (RS) Level 3, EN 61000-4-4 (EFT) Level 4, EN 61000-4-5 (Surge) Level 3, EN 61000-4-6 (CS) Level 3, EN 61000-4-8, EN 61000-4-11, EN 61000-4-12 |
Marine | DNV |
Shock | IEC 60068-2-27 |
Freefall | IEC 60068-2-32 |
Vibration | IEC 60068-2-6 |
• Reliability | |
MTBF (mean time between failures) | MGate MB3170: 210,794 hrs MGate MB3270: 125,234 hrs |
• Warranty | |
Warranty Period | 5 years |
Reviews